Configuration
The heating element can be either high temperature PVC or silicone insulated heating cable. This cable is placed between-two aluminum sheets.The aluminum foil element has adhesive backing as standard for quick and easy fixing to the area requiring temperature-maintenance.Cut outs in the material are possible, allowing for perfect fitting to the part on which the element will be mounted.
Applications
— Defrost or freeze protection of refrigerator or ice box
— Freeze protection of plate heat exchangers
— Temperature maintenance of heated food counters in canteens
— Anti-condensation of electronic or electric control boxes
— Hermetic compressors heating
— Anti-condensation of bathrooms mirrors
— Anti-condensation of refrigerated display cabinets
— Domestic appliances, medical...
|
|
RLPV |
RLPG |
|
Electrical insulation |
105℃PVC |
Silicon rubber |
|
Dimension |
Any dimension on request |
|
Voltage |
Any voltage on request |
|
Output |
Up to 2.5KW/m2 |
|
Tolerances |
≤±5% |
|
Insulation resistance in normal temperature |
≥100 MΩ |
|
Dielectric strength in normal temperature |
1800V 2S, No flashover and break down |
|
Leakage current in working temperature |
≤0.02 mA/m |
|
Connect strength |
Heater wire and lead wire |
≥36N 1min |
|
Lead wire and terminal |
≥58.8N 1min |
|
Heater and Al-foil |
400g/ 1min |
Note:
- Temperature control
- Cut out the hole in aluminum foil
- Earthing of the aluminum foil